Greetings,
I've recently heard from a peer that the Delsys system operates with an HPF of 20 Hz. If this is the case, the data acquired wouldn't...
Announcement
Collapse
No announcement yet.
Search Result
Collapse
7 results in 0.0099 seconds.
Keywords
Members
Tags
-
Wireless Delsys Trigno System: In-line hardware high-pass filter
-
Filtering kinematics and kinetics for inverse dynamic parameters- what is best prac?
Hi,
I am starting another thread to discuss this issue which I have encountered in the BJSM paper by Hewett's group and van den Bogert's...Last edited by Bernard; December 9, 2014, 07:44 AM.
-
Optimum cut off frequency estimation by Yu (1999)
Hi there,
I'm trying to estimate the optimum cut off frequency for kinematic data. I have calculated the optimum cut off value in excel...
-
dealing with Heart Rate with EMG Signals
Hello everyone,
We have a Delsys wireless EMG system (trigon). Although not apparent in the signal it self and for my own knowledge, how...
-
Low pass filter order
Hi All,
I am trying to ascertain the correct way to name a low pass filter. If I follow the examples as detailed in Robertson and Dowling...
-
Filtering Biodex data
Good day all,
What are people's thoughts on filtering the raw data from Biodex tests? I'm leaning towards filtering out the inital acceleration...
-
FeatureFinder 2.2.0: A free tool for visual review, filtering, and feature extraction
Hello,
A couple weeks ago, we posted at BIOMCH-L about a free software tool—FeatureFinder—for the processing and feature extraction...